Heater and Flue Installer Terms and Conditions SA: Wood Heater Installation Contracts
Book a free 30-minute callCall (08) 7094 2021
Same-day response. Prefer to text? WhatsApp us
Heater and flue installer terms and conditions in South Australia
A wood heater burns fuel inside the house, and its flue carries the smoke out through the roof. South Australian law sets rules for wood and gas heaters alike: an environment protection policy controls which wood heaters can be installed and how, and connecting a gas heater is licensed gas fitting with certificate requirements. Heater and flue installer terms and conditions turn those rules into a quote the customer signs. Talon Legal drafts quotes, installation terms and sales paperwork for South Australian heater retailers and installers. Book a same-day free 30-minute consultation or call (08) 7094 2021.
Heater and flue installer terms and conditions SA key facts
| Issue | Position for heater and flue installers in South Australia |
|---|---|
| Governing law | Environment Protection (Air Quality) Policy 2016 (SA); Gas Act 1997 (SA); Plumbers, Gas Fitters and Electricians Act 1995 (SA); Building Work Contractors Act 1995 (SA) and Regulations 2026; Australian Consumer Law. Current to 22 November 2026. |
| Wood heaters | A solid fuel heater must not be installed unless it is marked as compliant with AS/NZS 4012:2014 and AS/NZS 4013:2014 (clause 10(1)). |
| Installation standard | The installer must comply with the mandatory measures of AS/NZS 2918:2001 and those standards, and have regard to their recommended measures (clause 10(2), (3)). |
| Gas heaters | A gas fitting business needs a contractor's licence and its workers need registration (Plumbers, Gas Fitters and Electricians Act sections 6(1), 13); the work must meet the gas regulations, including the certificate requirements (Gas Act section 56). |
| Rectification | The Technical Regulator can direct that an unsafe or non-compliant gas installation be rectified, including by the person who did the work within 2 years before the direction (Gas Act section 57). |
| Builders licence | A flue cut through a ceiling and roof can make the job building work (section 3(1)(a)), and a business that does building work for others needs a licence (section 6(1)). |
| First step | Same-day free 30-minute consultation. Call (08) 7094 2021. |
Need heater and flue installer terms and conditions? What this guide covers
This guide covers what is particular to heater and flue installer terms and conditions in South Australia, current to 22 November 2026: the wood heater rules, gas heater compliance, when the job is building work, what the quote should record, naming the right customer, and sales in the showroom and the home. Ducted gas heating is covered in the ducted heating installer guide.
We act for wood heater retailers and installers, gas heater installers, flue and chimney specialists, and the gas fitters who connect heaters for retailers.
Free Consultation. Send us the quote, terms and sales forms you use for heater installations. Book a same-day free 30-minute consultation or call (08) 7094 2021.
On this page
- The wood heater rules
- Gas heaters: licences and compliance
- Is a heater and flue installation building work?
- What a heater installation quote should record
- Naming the right customer
- Selling heaters in the showroom and the home
- What the heater pack holds
- How similar matters tend to play out
- Heater and flue case law
- How we build heater and flue installer terms and conditions
- Frequently asked questions
- Related trade contract guides
The wood heater rules
South Australia regulates wood heaters through the Environment Protection (Air Quality) Policy 2016. A solid fuel heater is any solid fuel burning appliance designed, manufactured or adapted for use in domestic premises, whether or not it is used there (clause 3(1)), so the rules reach a heater installed in a shed or a cafe if it is that kind of appliance.
| Rule | What it requires |
|---|---|
| Compliance marking | A person must not install a solid fuel heater unless it is marked as compliant with AS/NZS 4012:2014 and AS/NZS 4013:2014 (clause 10(1)) |
| Mandatory measures | When installing, the installer must comply with the mandatory measures of AS/NZS 2918:2001, AS/NZS 4012:2014 and AS/NZS 4013:2014 that apply to that kind of heater (clause 10(2)) |
| Recommended measures | The installer must have regard to the recommended measures of the same standards (clause 10(3)) |
| Offences | Clauses 10(1) and 10(2) are mandatory provisions, each marked as a Category B offence |
The obligation sits with the person who installs the heater. A retailer that books the installation, with its own staff or a contractor, should record the model and its compliance marking in the quote, and the installation record should show how the heater, flue and hearth were installed, so the business can show the mandatory measures were met.
Before your next heater installation quote goes out. Book a same-day free 30-minute consultation or call (08) 7094 2021.
Gas heaters: licences and compliance
Connecting a gas heater is gas fitting. Carrying on business as a gas fitting contractor needs a licence, and the person who does the work must be authorised by registration (Plumbers, Gas Fitters and Electricians Act sections 6(1), 13).
- The work must meet the regulations. A licensed gas fitting contractor engaged for the work must see that the work and its examinations and tests meet the regulations (Gas Act section 56(1), (3)(a)).
- Certificates. Where a registered gas fitting worker does the work, the notification and certificate of compliance requirements must be met (section 56(2)).
- Two years. The Technical Regulator can direct that an unsafe or non-compliant installation be rectified, including by the person who did the work within 2 years before the direction (section 57).
- Retailers. A heater retailer that is not a gas fitting contractor should engage one for the connection and say so in the quote, so the customer knows who issues the certificate.
Is a heater and flue installation building work?
It can be. The regulations do not name heaters or flues in their list of building work (Building Work Contractors Regulations regulation 4), so the question turns on the definition in the Act, which includes the work of altering, improving or adding to a building (section 3(1)(a)). A freestanding heater placed on an existing hearth and connected to an existing flue may not meet that definition. A flue cut through a ceiling and roof, with a new hearth and flashing, can be altering the building.
| Job | Position |
|---|---|
| Gas fitting for a gas heater | Prescribed building work (regulation 4(1)(h)); a gas fitting contractor is exempt from the builders licence for work its gas licence authorises (regulation 5(1)) |
| New flue through ceiling and roof | Can be building work under section 3(1)(a) |
| Heater on an existing hearth with an existing flue | Can fall outside the definition, depending on the work done |
| On a house | Building work on a house is domestic building work, and a contract of $20,000 or more must comply with section 28 |
Where the job is building work, the business needs a builders licence (section 6(1)) and, without one, recovers no fee or other consideration unless a court finds the failure resulted from inadvertence only (section 6(2)). Allied Grain Systems shows how that exception works for a business that did not know it needed a licence ([39], [41]).
What a heater installation quote should record
| Quote term | What it settles |
|---|---|
| The heater | Make, model and compliance marking |
| Heating area | The room or area the heater is to warm, as the customer described it |
| The flue system | The flue kit, its height above the roof and the cowl |
| Clearances and hearth | The clearances to walls and combustibles, and the hearth or floor protector the installation instructions call for |
| Roof and ceiling | Penetrations, flashing and who makes good the ceiling around the flue |
| Access | Roof access equipment and the height of the roof |
| The old heater | Whether the old heater and flue are removed and disposed of |
| Approvals | Who is responsible for any council, strata or landlord approval |
| Exclusions | Electrical work for fans, firewood, and repairs to existing chimneys |
The heating area matters. A customer who makes the area to be heated known and relies on the business’s skill or judgment gets the benefit of the guarantee that the heater is reasonably fit for that purpose (Australian Consumer Law section 55). Recording the area in the quote is what lets the business show the heater was sized for it.
Naming the right customer
Heaters are bought for homes, cafes, offices and shops. Where the premises belong to a business, the quote should name the business as the customer.
Christopoulos shows the problem. A gas and plumbing business quoted for work at a laundromat, the quote was accepted and a deposit was paid ([6]), and an invoice for the work done went unpaid. The business obtained summary judgment against the director personally. On review, the District Court set it aside and entered judgment against his company for the work done, including the hot water heater and flue ([28] to [30]). The quote and acceptance form should record the customer’s legal name and ABN, and the person who signs should sign for that customer.
Selling heaters in the showroom and the home
A heater sold at the customer’s home can be an unsolicited consumer agreement. That happens where the agreement is negotiated in person away from the business premises, or by phone, without the customer inviting the dealer to negotiate that supply, and the price is over $100 or cannot be worked out when it is made (Australian Consumer Law section 69(1)). A request for a quote is not an invitation to negotiate (section 69(2)).
| Rule | Effect for a heater business |
|---|---|
| Termination | The customer can terminate within ten business days, longer where listed requirements are not met (section 82(1), (3)) |
| No supply or payment | Nothing may be installed, and no payment accepted, in those ten business days (section 86(1)) |
| Guarantees on the heater | Acceptable quality, and a match with its description and any sample or demonstration model (sections 54, 56, 57) |
| Guarantees on the installation | Due care and skill (section 60), and fitness for a purpose the customer made known (section 61) |
| Warranty document | A warranty against defects must be in a document that meets regulation 90 of the Competition and Consumer Regulations (section 102) |
Where every negotiation takes place in the showroom, section 69 does not apply, because it turns on negotiations away from the business premises or by phone. A business that measures, quotes and sells in the home needs paperwork built for those rules.
What the heater pack holds
A heater pack is built from our masters and a heater schedule, and quoted as a fixed fee before we start.
- A quote and acceptance form recording the heater, compliance marking, heating area, flue system, clearances and exclusions.
- An installation record for the standards’ mandatory measures and the gas compliance certificate.
- Terms for showroom sales and paperwork for sales made in the home.
- A homeowner contract for jobs that are domestic building work.
- An installation warranty document that meets regulation 90.
How similar matters tend to play out
These are illustrations built from the rules above, not predictions. Every job turns on its own contract and facts.
The heater without the marking. A customer asks the installer to fit a second-hand wood heater bought online. It carries no compliance marking. The terms let the installer decline any heater that is not marked as compliant, and the quote is withdrawn.
The smoky lounge. A customer says the new heater smokes into the room. The installer’s record shows the flue kit, flue height and cowl that were quoted and installed, and the checks made on the day, so the inspection starts from what was done.
The cafe owner. A cafe owner signs a heater quote in his own name, but the cafe is run by his company. The salesperson corrects the quote to name the company and records its ABN before installation.
Heater and flue case law
None of the decisions below concerned a wood heater. One decided who owed for installation work that included a hot water heater and flue; the other decided when a business without a licence can still recover.
| Case | Court | Principle | Pinpoint |
|---|---|---|---|
| Christopoulos v BN and R Roberts Pty Ltd [2019] SADC 97 | District Court | An invoice for gas and water work, including a hot water heater and flue, was payable by the director's company, and summary judgment against the director personally was set aside | [6], [26] to [30] |
| Allied Grain Systems Pty Ltd v Inheritance Capital Asset Management Pty Ltd [2023] SASC 175 | Supreme Court | Ignorance of the obligation to be licensed can be inadvertence under section 6(2)(b), absent wilful failure to inquire or reckless indifference | [5], [38], [39], [41] |
Case notes
Christopoulos v BN and R Roberts Pty Ltd [2019] SADC 97
A plumbing and gas fitting business gave a written quote of $13,989 including GST for gas, water and waste work at a laundromat; the quote was accepted and a $2,000 deposit paid ([6]). On review, the director accepted that his company owed something for the work done ([26]), and the company was joined as a party ([27]). Judge Durrant found the invoice of $11,888.18, covering work that included the hot water heater and flue, was payable by the company ([28]). The summary judgment against the director was set aside, and judgment was entered against the company with interest ([29], [30]).
Allied Grain Systems Pty Ltd v Inheritance Capital Asset Management Pty Ltd [2023] SASC 175
A company that had performed building work under a contract without a South Australian licence asked the Court to find its failure resulted from inadvertence only, so it could recover $1,139,121.59 ([5]). Stanley J rejected the argument that the company had wilfully failed to inquire or was recklessly indifferent ([38]). His Honour held that the statutory test of inadvertence is met where the failure is due to ignorance of the obligation to be licensed, unless there is a wilful failure to inquire or reckless indifference ([39]), and found the failure resulted from inadvertence only ([41]).
How we build heater and flue installer terms and conditions
We start with what you sell and how: wood or gas, retail showroom or home visits, your own installers or contractors.
| Stage | What happens | What we do |
|---|---|---|
| 1. Intake | A questionnaire on your products, installers, gas fitters and sales channels | We check the gas licences, the wood heater rules and whether your jobs are building work |
| 2. Review | Your quotes, sales forms, installation records and warranty document | We mark the gaps on compliance marking, clearances, approvals and customer names |
| 3. Drafting | Masters and the heater schedule | We draft the quote, installation record, sales paperwork and warranty document |
| 4. Delivery | Word documents ready for the next season | We brief your sales and install teams on the records that matter |
We cannot promise that terms prevent every complaint about a smoky room or a cold house. A quote that records the heater, the flue and the area to be heated, with an installation record against the standard, answers the complaint with what was agreed and done.
When a customer disputes a heater invoice. Book a same-day free 30-minute consultation or call (08) 7094 2021.
Frequently asked questions
Is a free wood heater installation template enough in SA?
Not on its own. A template that is not written for South Australia will not deal with the wood heater rules on compliance marking and installation standards, the gas compliance steps, or the builders licence where a new flue makes the job building work. It also will not record the heater, flue and heating area that decide a complaint.
Can any wood heater be installed in South Australia?
No. A person must not install a solid fuel heater unless it is marked as compliant with AS/NZS 4012:2014 and AS/NZS 4013:2014 (Environment Protection (Air Quality) Policy 2016 clause 10(1)).
Which standard governs wood heater installation?
The installer must comply with the mandatory measures of AS/NZS 2918:2001, AS/NZS 4012:2014 and AS/NZS 4013:2014 that apply to that kind of heater, and have regard to their recommended measures (clause 10(2), (3)).
Who can connect a gas heater?
A licensed gas fitting contractor, with the work done by a person authorised by registration (Plumbers, Gas Fitters and Electricians Act sections 6(1), 13). The work must meet the gas regulations, including their certificate requirements (Gas Act section 56).
Does a heater installer need a builders licence?
Where the job is building work, yes. Cutting a new flue through a ceiling and roof can be altering a building (section 3(1)(a)). A gas fitting contractor is exempt only for work its gas licence authorises (regulation 5(1)).
What if a heater business installed without a licence it needed?
It recovers no fee or other consideration unless a court finds the failure resulted from inadvertence only (section 6(2)). In Allied Grain Systems, ignorance of the obligation was treated as inadvertence ([39], [41]).
Who should be named as the customer on a heater quote?
The person or business that will pay, by its legal name. In Christopoulos, summary judgment against a director personally was set aside and judgment was entered against his company ([29], [30]).
Can a customer cancel a heater bought at home?
Where the sale is an unsolicited consumer agreement, yes, within ten business days, and nothing may be supplied or paid for in that time (Australian Consumer Law sections 82, 86).
What should a heater installation warranty include?
A warranty against defects must be in a document that meets regulation 90 of the Competition and Consumer Regulations, including the business’s details, the claim procedure and the prescribed statement (Australian Consumer Law section 102).
Do I need a lawyer for heater and flue installer terms and conditions?
The law does not require one, but the wood heater rules, gas compliance, licensing and consumer law all meet in the same quote. We draft heater and flue installer terms and conditions for South Australian heater businesses that want each installation on the record.
Related trade contract guides
Related guides
- Plumbing and electrical contracts SA
- Ducted heating installer terms and conditions SA
- Gas fitter terms and conditions SA
- Appliance installer terms and conditions SA
- Ventilation installer terms and conditions SA
- Renovation builder terms and conditions SA
- Builders licence SA
- Minor domestic building work SA
- Trade contracts SA
- Subcontractor agreements